Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz J Cardiovasc Surg ; 31(5): 351-357, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27982343

RESUMO

Objective: Composite graft of left internal thoracic artery and great saphenous vein in revascularization of the left coronary system is a technique well described in literature. The aim of this study is to analyze blood flow dynamics in this configuration of composite graft especially in what concerns left internal thoracic artery's adaptability and influence of great saphenous vein segment on left internal thoracic artery's flow. Methods: Revascularization of left coronary system with composite graft, with left internal thoracic artery revascularizing the anterior interventricular artery and a great saphenous vein segment, anastomosed to the left internal thoracic artery, revascularizing another branch of the left coronary system, was performed in 23 patients. Blood flow was evaluated by transit time flowmetry in all segments of the composite graft (left internal thoracic artery proximal segment, left internal thoracic artery distal segment and great saphenous vein segment). Measures were performed in baseline condition and after dobutamine-induced stress, without and with non-traumatic temporary clamping of the distal segments of the composite graft. Results: Pharmacological stress resulted in increase of blood flow values in the analyzed segments (P<0.05). Non-traumatic temporary clamping of great saphenous vein segment did not result in statistically significant changes in the flow of left internal thoracic artery distal segment, both in baseline condition and under pharmacological stress. Similarly, non-traumatic temporary clamping of left internal thoracic artery distal segment did not result in statistically significant changes in great saphenous vein segment flow. Conclusion: Composite grafts with left internal thoracic artery and great saphenous vein for revascularization of left coronary system, resulted in blood flow dynamics with physiological adaptability, both at rest and after pharmacological stress, according to demand. Presence of great saphenous vein segment did not alter physiological blood flow dynamics in distal segment of left internal thoracic artery.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ponte de Artéria Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Anastomose de Artéria Torácica Interna-Coronária , Artéria Torácica Interna/fisiologia , Veia Safena/fisiologia , Idoso , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Enxerto Vascular , Grau de Desobstrução Vascular/fisiologia , Resistência Vascular/fisiologia
2.
Rev. bras. cir. cardiovasc ; 31(5): 351-357, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-829758

RESUMO

Abstract Objective: Composite graft of left internal thoracic artery and great saphenous vein in revascularization of the left coronary system is a technique well described in literature. The aim of this study is to analyze blood flow dynamics in this configuration of composite graft especially in what concerns left internal thoracic artery's adaptability and influence of great saphenous vein segment on left internal thoracic artery's flow. Methods: Revascularization of left coronary system with composite graft, with left internal thoracic artery revascularizing the anterior interventricular artery and a great saphenous vein segment, anastomosed to the left internal thoracic artery, revascularizing another branch of the left coronary system, was performed in 23 patients. Blood flow was evaluated by transit time flowmetry in all segments of the composite graft (left internal thoracic artery proximal segment, left internal thoracic artery distal segment and great saphenous vein segment). Measures were performed in baseline condition and after dobutamine-induced stress, without and with non-traumatic temporary clamping of the distal segments of the composite graft. Results: Pharmacological stress resulted in increase of blood flow values in the analyzed segments (P<0.05). Non-traumatic temporary clamping of great saphenous vein segment did not result in statistically significant changes in the flow of left internal thoracic artery distal segment, both in baseline condition and under pharmacological stress. Similarly, non-traumatic temporary clamping of left internal thoracic artery distal segment did not result in statistically significant changes in great saphenous vein segment flow. Conclusion: Composite grafts with left internal thoracic artery and great saphenous vein for revascularization of left coronary system, resulted in blood flow dynamics with physiological adaptability, both at rest and after pharmacological stress, according to demand. Presence of great saphenous vein segment did not alter physiological blood flow dynamics in distal segment of left internal thoracic artery.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veia Safena/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ponte de Artéria Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Anastomose de Artéria Torácica Interna-Coronária , Artéria Torácica Interna/fisiologia , Resistência Vascular/fisiologia , Grau de Desobstrução Vascular/fisiologia , Estudos Prospectivos , Enxerto Vascular , Período Intraoperatório
4.
Rev. bras. cir. cardiovasc ; 19(1): 1-8, jan.-mar. 2004. ilus, tab
Artigo em Português | LILACS | ID: lil-363352

RESUMO

OBJETIVO: Verificar o comportamento do fluxo sangüíneo na artéria torácica interna esquerda (ATIE), quando utilizada para revascularizar a artéria interventricular anterior (AIA) e mais um ramo do sistema coronariano esquerdo (SCE). MÉTODO: No presente estudo, compara-se o fluxo obtido pela ecocardiografia Doppler na ATIE, em repouso e sob estresse com dobutamina, em dois grupos de 20 pacientes cada. No grupo A, foi utilizado enxerto pediculado de ATIE anastomosada unicamente à AIA. No grupo B, a ATIE revasculariza a AIA, e um enxerto de veia safena magna, anastomosado em "Y" à ATIE, revasculariza outro ramo do SCE. O estudo angiográfico demonstrou patência de todos os enxertos em ambos os grupos. Na avaliação pela ecocardiografia Doppler foram realizadas as seguintes medidas: débitos sistólico (DS), diastólico e total, razão entre o débito total em estresse pelo débito total em repouso (DTE/DTR), velocidades de pico sistólico (VPS) e diastólico e razão entre essas velocidades. RESULTADOS: Todos os parâmetros analisados apresentaram diferença estatisticamente significativa, com exceção do DS, DTE/DTR e VPS. CONCLUSAO: Nas condições e métodos usados neste estudo, pode-se inferir que o fluxo sangüíneo na ATIE no enxerto composto (Grupo B) é maior que no enxerto simples (Grupo A), o que demonstra a grande capacidade da ATIE em adaptar-se à demanda de fluxo.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Dobutamina/administração & dosagem , Heparina/administração & dosagem , Artérias Torácicas , Anastomose de Artéria Torácica Interna-Coronária , Ecocardiografia Doppler , Ecocardiografia sob Estresse , Revascularização Miocárdica
5.
Rev. bras. cir. cardiovasc ; 18(1): 15-22, Jan.-Mar. 2003. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-365285

RESUMO

INTRODUÇAO: O procedimento de Vineberg consiste no implante da artéria torácica interna na musculatura isquêmica do ventrículo esquerdo. O principal questionamento acerca desse procedimento é a capacidade de fornecimento de fluxo sanguíneo adequado para o miocárdio isquêmico. OBJETIVOS: Avaliar os resultados angiográficos do procedimento de Vineberg pela técnica de Vineberg modificada por Lobo Filho e a morbi-mortalidade no pós-operatório imediato (POI), bem como analisar o fluxo na artéria torácica interna esquerda (ATIE) implantada, em repouso e estresse. MÉTODO: De setembro de 1999 a abril 2002, em nosso serviço, oito pacientes foram operados pela técnica supracitada, na qual a introduçäo da artéria torácica interna na intimidade da musculatura do ventrículo esquerdo foi realizada com auxílio de um "kit" destinado à introduçäo de marcapassos cardíacos endocárdicos definitivos por punçäo da veia subclávia. Após seis meses, os pacientes foram estudados angiograficamente e submetidos ao ecodoppler da ATIE implantada. Para estudo do fluxo da ATIE pelo ecodoppler, constituímos dois grupos: "Grupo Vineberg", composto pelos oito pacientes citados; e o "Grupo Controle", composto por vinte pacientes, nos quais a ATIE foi utilizada para revascularizar diretamente a artéria interventricular anterior. O estudo angiográfico demonstrou perviabilidade de todos os enxertos em ambos os grupos. No estudo pelo ecodoppler, foram realizadas medidas de débito e velocidade de fluxo no enxerto. A análise dos dados obtidos foi feita pelo teste-T para amostras pareadas e näo pareadas. RESULTADOS: Näo houve óbitos ou complicações no POI. O estudo angiográfico demonstrou perviabilidade em 100 por cento dos casos. O débito total observado foi cerca de 55 por cento daquele encontrado no Grupo Controle. Em ambos os grupos, o débito total aumentou do repouso para o estresse. CONCLUSAO:A técnica de Vineberg modificada por Lobo Filho pode ser utilizada com baixas taxas de morbi-mortalidade, alto índice de perviabilidade, oferecendo fluxo sanguíneo significativo em repouso e sob estresse.


Assuntos
Humanos , Dobutamina , Ecocardiografia Doppler , Revascularização Miocárdica/métodos , Dissecação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...